Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Mobile Multi-parameter Analyzer, BEP-M1000Y is listed in VVON's ph conductivity & water analysis range for Bangladesh. Published details include Wavelength Range: 380-800nm; 1.pH measurement range: (-1.99 ~ 19.99) pH: 1.pH measurement range: (-1.99 ~ 19.99) pH. Match measured parameters, range, probe compatibility and sample conditions. For a quotation, send the water or sample type, parameters, range, probe and calibration requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Indication Error | ≤8% |
|---|---|
| Repeatability | ≤±3% |
| Optical Stability | ≤0.001A/10min |
| Light Source Life | 100,000 hours |
| Measurement Time | 10 minutes |
| Number of Curves | 200 items can be set |
| Data Storage | Can store more than 2000groups |
| Wavelength Range | 380-800nm |
| Display | 7.0-inch color touch screen/ 5.6-inch Omron button integrated screen |
| Printer | Built-in thermal printer |
| Colorimetric Method | Colorimetric tube colorimetry |
| Data Communication | USB interface |
| Ambient Temperature | 5~35℃ (level 0.01); 15~30℃(level 0.001) |
| Ambient Humidity | ≤75% |
| Rated Voltage | AC 220V±10%/50Hz |
| Rated Power | 300W |
| 1.pH measurement range: (-1.99 ~ 19.99) pH | 1.pH measurement range: (-1.99 ~ 19.99) pH |
|---|---|
| Resolution | 0.1/0.01 |
| Accuracy | Electric meter: ±0.01 pH, matching: ±0.02 pH |
| Input Current | ≤1×10^(-12) A |
| Input Resistance | ≥3×10^(12) Ω |
| Stability | ±0.01 pH/3h |
| Temperature Compensation Range | Manual/automatic (0~100.0)℃ |
| mV Measurement Range (mV/ORP/EH): -2000mV ~ 0 ~ 2000mV | mV Measurement Range (mV/ORP/EH): -2000mV ~ 0 ~ 2000mV |
| Resolution | 1mV |
| Accuracy | ±0.1% FSmV |
| 2. ※Conductivity measurement range: (0.00~20.00) μS/cm (20.0~200.0) μS/cm (200~2000)μS/cm (2.00~20.00)mS/cm (20.0~200.0) mS/cm (200~2000) mS/cm (K=10) | 2. ※Conductivity measurement range: (0.00~20.00) μS/cm (20.0~200.0) μS/cm (200~2000)μS/cm (2.00~20.00)mS/cm (20.0~200.0) mS/cm (200~2000) mS/cm (K=10) |
| Resistivity | (0 ~ 100) MΩ·cm |
| TDS | (0 ~ 100) g/L |
| Salinity | (0 ~ 100) ppt |
| Resolution | 0.01/0.1/1μS/cm 0.01/0.1/1mS/cm |
| Accuracy | Electric meter: ±0.5% FS, matching: ±1.0% FS |
| Temperature Compensation Range | (0 ~ 100)℃ (manual/automatic) |
| Electrode Constant | 0.1/1/10cm^(-1) |
| Reference Temperature | 25℃, 20℃ and 18℃ |
| 3. Dissolved oxygen measurement range: (0 ~ 20.00) mg/L (ppm) (0 ~ 200.0)% | 3. Dissolved oxygen measurement range: (0 ~ 20.00) mg/L (ppm) (0 ~ 200.0)% |
| Resolution | 0.1/0.01 mg/L(ppm) 1/0.1 % |
| Accuracy | Electric meter: ±0.10 mg/L, matching: ±0.40 mg/L |
| Response Time | ≤10s |
| Stability | (±0.07mg/L)/1h |
| Temperature Compensation Range | (0 ~ 100)℃ (automatic/manual) |
| Salinity Compensation Range | (0 ~ 45) ppt (automatic) |
| Air Pressure Compensation Range | (0~200) kPa (automatic) |
| Electrode Type: Fluorescence dissolved oxygen sensor | Electrode Type: Fluorescence dissolved oxygen sensor |
| Temperature Measurement Range | 0℃~ 100℃ |
| Resolution | 0.1℃ |
| Accuracy | 5~60℃ range: ±0.4℃, Other ranges: ±0.8℃ |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temperature / Range: 0~100°C/32~212°F. Match measured parameters, range, probe compatibility and sample conditions.
Wavelength Range: 190-1100nm. Match measured parameters, range, probe compatibility and sample conditions.
Digestion Capacity: 0-10mL. Match measured parameters, range, probe compatibility and sample conditions.