Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Microplate Incubator, DBI-PR80-5 is listed in VVON's microplate readers & washers range for Bangladesh. Published models: DBI-PR80-5. Published details include Temp display range: 0℃~100℃; Temp control range: RT+5℃~100℃. Compare assay format, wavelength requirements, plate compatibility and data handling. For a quotation, send the assay type, plate format, wavelengths and daily workload. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | DBI-PR80-5 |
|---|---|
| Temp display range | 0℃~100℃ |
| Temp control range | RT+5℃~100℃ |
| Time range | 1min ~ 99h59min/∞ |
| Speed range | 200~1600rpm |
| Orbit | 3mm |
| Temp accuracy | ≤±0.5℃@37℃* |
| Display accuracy | 0.1℃ |
| Temp uniformity | ≤±0.5℃@37℃* |
| Heating time 1 | <5min(from 25℃ to 60℃)* |
| Heating time 2 | ≤20min(from 25℃ to 100℃)* |
| Auto preheating | Yes |
| Preheating setting range | 37℃~100℃ |
| Pause function | Yes |
| Auto resume to run | Yes |
| Auto fan function | Yes |
| Independent timing function | Yes |
| Heating lid temp. control mode | Automatic / Manual |
| Multi point running | Yes(Max 5points) |
| Multi cycle | Yes(Max 99times) |
| Capacity | 6 Microplates or Deepwell plates |
| Power | 480W |
| Electricity | AC220V or AC110V /50-60HZ |
| Dimension | 481*346*228(mm) |
| Weight | 15kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temp. display range: 0℃~80℃; Temp. control range: RT+5℃~80℃. Compare assay format, wavelength requirements, plate compatibility and data handling.
Sample Capacity: 2plates. Compare assay format, wavelength requirements, plate compatibility and data handling.
Microplate Readers & Washers by Infitek. Compare assay format, wavelength requirements, plate compatibility and data handling.