Skip to main content

Infitek Liquid Chromatograph, HPLC-6000

Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Liquid Chromatograph, HPLC-6000 is listed in VVON's chromatography systems & consumables range for Bangladesh. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications 1
More advanced technology More stable performance More reliable use More flexible configuration
Manufacturer specifications 2
Sample: alkylphenol Compounds (9 Components)HFM Gradient Mode:high Frequency Mode HFM
Column: C18 4.6x150mm(5μm)Gradient: a:b (Min)=65:35(0)→5:5(15)→5:95(20) →65:35(20.1)→65:35(30)
Temperature: 40℃Injection:10ml (100ppm)
Mobile Phase: A Water + 0.1% Trifluoroacetic B Acetonitrile + 0.1% Trifluoroacetic Acid Acid
Manufacturer specifications 3
Low sample residue Reduce sample waste, reduce sample residue and improve injection reproducibility; Improving the injection speed is beneficial for high-throughput sample analysis; The optimized injection system cleaning method further reduces sample residue.
Sampler with thermo rack (optional) The system uses Peltier temperature control module to accurately stabilize the temperature of the sampler at the set value and ensure the stability of temperature sensitive samples.Sampler with thermo rack (optional) The system uses Peltier temperature control module to accurately stabilize the temperature of the sampler at the set value and ensure the stability of temperature sensitive samples.
For temperature sensitive samples, the sample analysis is carried out without the temperature control of the injection system. The increase of external temperature will lead to the generation of impurities, and the impurities will gradually increase and become larger.
For the same sample, the sample was analyzed at 4℃ in the sampling system, and the analysis results did not change with the passage of time.
Humanized sample rack design The inner part of the instrument is designed to prevent condensation and improve the service life of the instrument.
Manufacturer specifications 4
Mobile phase preheating function The mobile phase is preheated before entering the column to reduce the interference to the temperature environment in the column; The air inside the column oven always circulates to ensure the constant ambient temperature around the column; Ensure that the internal temperature of the chromatographic column is constant during the experiment.

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment

View full category