Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Liquid Chromatograph, HPLC-2025 is listed in VVON's chromatography systems & consumables range for Bangladesh. Published details include Sample Capacity: 108, 2mL(96&384 well plates); Temperature Range: 5 ℃ above ambient to 85 ℃ 10 ℃ below ambient to 85 ℃. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Flow Rate Range | 0.001mL/min~10.000mL/min |
|---|---|
| Pump Type | Isocratic(P1), Binary(P2), Quaternary(P4) |
| Maximum Pressure | 62MPa |
| Plunger Rinsing | Supported |
| Sample Capacity | 108, 2mL(96&384 well plates) |
|---|---|
| Injection Range | 0-100μL |
| Injection Mode | Low-loss, microliter carrying, full-loop |
| Injection Time | Minimum to 5 s |
| Carryover | 0.003% |
| Degassing Unit | Online degassing(optional) |
| Temperature Control | 4-40 ℃(optional) |
| Operating Principle | Peltier element and fan-based forced air |
|---|---|
| Temperature Range | 5 ℃ above ambient to 85 ℃ 10 ℃ below ambient to 85 ℃ |
| Light Source | Deuterium(transmission type) and Tungsten lamp |
|---|---|
| Wavelength Range | 190-800nm |
| Wavelength Accuracy | +/- 1nm |
| Wavelength Precision | +/- 0.1nm |
| Linearity | >2.5 AU |
| Wavelength Calibration | Mercury lamp |
| Light Source | Deuterium (transmission type) & Tungsten lamp |
|---|---|
| Wavelength Range | 190~800nm |
| Slit Width | 1nm, 2nm, 4nm, 8nm |
| Wavelength Accuracy | +/- 1nm |
| Wavelength Precision | +/- 0.1nm |
| Linearity | > 2.0 AU |
| Wavelength Calibration | Holmium glass |
| Light Source | 150W Xe lamp |
|---|---|
| Wavelength Range(Excitation) | 200 to 850nm Zero order |
| Wavelength Range(Emission) | 250 to 900nm Zero order |
| Detection Sensitivity (Raman peak of water S/N) | S/N ≥ 900 (Baseline method) |
| Wavelength Accuracy | ±3nm |
| Wavelength Repeatability | ±0.5nm |
| Noise | ≤0.05mV(1.0mL/min 100% Methanol, Gain 1.00) |
|---|---|
| Drift | ≤0.3mV/30 min(1.0mL/min 100% Methanol, Gain 1.00) |
| Min. Detection Limit | ≤5.0×10-6 g/mL(500pg) |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.