Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Halogen Moisture Analyzer, MCA Series is listed in VVON's moisture analysis & titration range for Bangladesh. Published models: MCA110-10, MCA110-5, MCA110-2, MCA110-1A. Match sample matrix, measurement method, concentration range and reagent needs. For a quotation, send the sample matrix, method, concentration range and throughput. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | MCA110-10 | MCA110-5 | MCA110-2 | MCA110-1A |
|---|---|---|---|---|
| Capacity | 110g | 110g | 110g | 110g |
| Readability | 0.01g | 0.005g | 0.002g | 0.001g |
| Operating Temp | 5℃-35℃ | 5℃-35℃ | 5℃-35℃ | 5℃-35℃ |
| Display | Backlit LCD | Backlit LCD | Backlit LCD | High Definition Backlit LCD |
| Calibration | External Calibration | External Calibration | External Calibration | External Calibration |
| Interface | RS232(Standard) | RS232(Standard) | RS232(Standard) | RS232(Standard) |
| Pan Size | Ø90mm | Ø90mm | Ø90mm | Ø90mm |
| Heating Source | Halogen Lamp-1 | Halogen Lamp-1 | Halogen Lamp-1 | Halogen Lamp-2 |
| Temp. Sensor | PT100 | PT100 | PT100 | PT100 |
| Temp. Range | 40℃-199℃ | 40℃-199℃ | 40℃-199℃ | 40℃-199℃ |
| Temp. Step | 1℃ | 1℃ | 1℃ | 1℃ |
| Moisture Range | 0.00%-100.00% | 0.00%-100.00% | 0.00%-100.00% | 0.00%-100.00% |
| Moisture Readability | 0.20% | 0.10% | 0.04% | 0.01% |
| Dry Range | 100.00%-0.00% | 100.00%-0.00% | 100.00%-0.00% | 100.00%-0.00% |
| Dry Readability | 0.20% | 0.10% | 0.04% | 0.01% |
| Temp Setting | 40℃-199℃ By 1℃ Step | 40℃-199℃ By 1℃ Step | 40℃-199℃ By 1℃ Step | 40℃-199℃ By 1℃ Step |
| Time Setting | 1-99min By 10s | 1-99min By 10s | 1-99min By 10s | 1-99min By 10s |
| Number of Storage | 15 | 15 | 15 | 15 |
| Heater | 220V ±15% 50Hz/110V±15% 60Hz/400W | 220V ±15% 50Hz/110V±15% 60Hz/400W | 220V ±15% 50Hz/110V±15% 60Hz/400W | 220V ±15% 50Hz/110V±15% 60Hz/400W |
| Balance | Input: 220V 50Hz/110V 60HZ Output: 9V | Input: 220V 50Hz/110V 60HZ Output: 9V | Input: 220V 50Hz/110V 60HZ Output: 9V | Input: 220V 50Hz/110V 60HZ Output: 9V |
| Chamber Height | 22mm | 22mm | 22mm | 22mm |
| External Dimension(W*D*H)(mm) | 280*250*180 | 280*250*180 | 280*250*180 | 280*250*180 |
| N.W.(kg) | 5.8 | 5.8 | 5.8 | 5.8 |
| Package Dimension (W*D*H)(mm) | 500*460*370 | 500*460*370 | 500*460*370 | 500*460*370 |
| G.W.(kg) | 7.1 | 7.1 | 7.1 | 7.1 |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Moisture Analysis & Titration by Infitek. Match sample matrix, measurement method, concentration range and reagent needs.
Capacity: 110g/1mg; Readability: 1mg. Match sample matrix, measurement method, concentration range and reagent needs.
Volume Range: 0.01mL-99.99mL, Max piston lift is 10mL, resolution is 10μL; Volume Accuracy: R=0.2% CV=0.07%. Match sample matrix, measurement method, concentration range and reagent needs.