Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Gas Chromatograph, GC-906 is listed in VVON's chromatography systems & consumables range for Bangladesh. Published models: GC-906. Match the analytical method, detector, column and sample-handling configuration. For a quotation, send the analytes, method, detector, columns, samples per day and utilities. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Extra-Large High-Definition Color Capacitive Touch Screen Equipped with a 10-inch color high-definition capacitive touch screen, it offers more sensitive and accurate touch control, allowing complex spectral details to be clearly visible. | |
|---|---|
| Intelligent Maintenance Tracking and Reminders Real-time monitoring of the instrument’s operating status and the usage of key components is available. Furthermore, based on the specific conditions and needs of the laboratory, the replacement cycle or threshold for the injection septum can be set in the smart control system, allowing the system to provide more accurate reminders for replacement times. | |
| High-Precision Gas Path Control System The new sample introduction system and advanced manufacturing materials, coupled with a full EPC (Electronic Pressure control) system, achieve a pressure control accuracy of up to 0.001 psi. It features ambient temperature and pressure compensation,and supports various operating modes such as constant flow, constant pressure, constant linear velocity, programmed pressure ramping, programmed flow ramping, and pulse injection, ensuring stable and accurate analysis processes. | |
| High-capacity oven design Featuring a large (≥23L) oven with advanced heating for fast, uniform temperature control of columns and flow paths, this system ensures high stability and accuracy. Its dual independent ovens easily support complex configurations like five valves and seven columns. | |
| Multiple inlet types, Quick-disconnect support The system offers compatibility with key inlets (e.g., split/splitless, packed), full software control of the liquid autosampler for single and sequence injection, and supports various techniques including valve, headspace, and thermal desorption injection. |
| ALS-24 Automatic Liquid Sampler Smart Guided Operation with step-by-step prompts. Enhanced Stability from encoder real-time feedback. Multi-Mode I/O for cross-vendor GC compatibility. Full Automation supporting 24/7 unattended operation. | |
|---|---|
| AHS-16 Headspace Autosampler An automatic headspace sampler is a sample preparation device for gas chromatography. It is a preferred method due to its simple operation, high efficiency, and superior reproducibility compared to alternatives like solvent extraction or thermal desorption. | |
| HGZ-300 Hydrogen Generator Operation & Display: Start gas production simply by turning on the power. Stable output pressure with flow rate clearly shown on an LED digital display. Maintenance & Usage: Routine maintenance only requires adding distilled water. Supports both continuous and intermittent operation. Design & Safety: Integrated design combining solution storage, electrolysis, and oxygen venting. Low cell temperature ensures long service life.Built-in anti-backflow device reliably prevents liquid return. | |
| GA-2009 Compressed Air Generator Deliver stable output pressure, low operating noise, and superior purification performance, making it an ideal alternative to high-pressure air cylinders. It is compatible with various domestic and imported gas chromatographs and can supply air for analytical laboratories. Additionally, it serves as a high-quality air source for high-purity nitrogen generators. |
| Natural gas sulfide analysis | Analysis of liquefied petroleum gas | Rapid Refinery Gas Analysis | Refinery flue gas analysis |
|---|
| GC-906 | |||
| Host | Host | Pressure/Flow Control | Supports up to 18 channels of electronic pressure/flow control (EPC) |
| Host | Host | Pressure Control Accuracy | 0.001psi |
| Host | Host | Number of sample ports supported | 3 |
| Host | Host | Maximum number of detectors supported | 4 |
| Host | Host | Temperature Control System | 8-channel independent temperature control system |
| Host | Host | Smart Maintenance Tracking and Reminders | yes |
| Column oven | Column oven | Control temperature | Room temperature+2℃ ~ 450℃ |
| Column oven | Column oven | Minimum step value | 0.01℃ |
| Column oven | Column oven | Maximum heating rate | ≥250ºC/min |
| Column oven | Column oven | Cooling time | From 450°C to 50°C in <3.2 minutes |
| Column oven | Column oven | Programmed Temperature Ramp | ≥99 steps 100 Platform |
| Column oven | Column oven | Temperature Stability | Ambient temperature ±1°C, column oven temperature variation <0.01°C |
| Column oven | Column oven | Others | 1. Automatic furnace chamber temperature protection function; 2. Dual column box independent temperature control |
| Injection System | Injection System | Injection type | Compatible with split/splitless capillary injectors, septum purging packed column injectors, cold column head injectors, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc. |
| Injection System | Injection System | Maximum operating temperature | 450℃ |
| Injection System | Injection System | Programmatic current increase | ≥ 10 steps |
| Injection System | Injection System | Stem pressure | 0~50psi、0-200psi |
| Injection System | Injection System | Pressure Control Accuracy | 0.001Psi |
| Injection System | Injection System | Maximum bypass ratio | 1:10000 |
| Injection System | Injection System | Flow Setting Range | 0~500ml/min; 0~1250ml/min |
| Injection System | Injection System | Flow Setting Accuracy | 0.01ml/min |
| Injection System | Injection System | Carrier Gas Control Mode | Constant pressure, constant flow rate, constant linear velocity, programmed pressure, programmed flow rate, programmed linear velocity, pulse injection |
| Injection System | Injection System | Others | Features an independent split cold trap and a septum purge trap |
| Detector | Hydrogen Flame Ionization Detector (FID) | Maximum operating temperature | 450℃ |
| Detector | Hydrogen Flame Ionization Detector (FID) | Detection limit | ≤1.1pg C/s(n-hexadecane) |
| Detector | Hydrogen Flame Ionization Detector (FID) | Baseline drift (30 min) | ≤2×10⁻^(13)A |
| Detector | Hydrogen Flame Ionization Detector (FID) | Baseline noise | ≤2×10^(⁻)^(14)A |
| Detector | Hydrogen Flame Ionization Detector (FID) | Dynamic Linear Range | ≥10⁷ |
| Detector | Hydrogen Flame Ionization Detector (FID) | Function | Auto-ignition function |
| Detector | Thermal Conductivity Detector (TCD) | Sensitivity | ≥12000mV.mL/mg |
| Detector | Thermal Conductivity Detector (TCD) | Baseline drift (30 min) | ≤0.2mV |
| Detector | Thermal Conductivity Detector (TCD) | Baseline noise | ≤0.05mV |
| Detector | Thermal Conductivity Detector (TCD) | Dynamic Linear Range | ≥10^(5) |
| Detector | Thermal Conductivity Detector (TCD) | Function | Air Gap Flow Protection Function |
| Detector | Flame Photometric Detector(FPD) | Maximum operating temperature | 450℃ |
| Detector | Flame Photometric Detector(FPD) | Detection limit | P≤80fg/s(Methyl parathion)、S≤8pg/s (Methyl parathion) |
| Detector | Flame Photometric Detector(FPD) | Dynamic Linear Range | P≥10^(3);S≥10^(2) |
| Detector | Flame Photometric Detector(FPD) | Function | Auto-ignition function |
| Detector | Electron Capture Detector (ECD) | radioactive source | 63Ni |
| Detector | Electron Capture Detector (ECD) | Maximum operating temperature | 400℃ |
| Detector | Electron Capture Detector (ECD) | Detection limit | ≤1.0×10^(-14) g/mL(γ-666) |
| Detector | Electron Capture Detector (ECD) | Dynamic Linear Range | ≥10^(4) |
| Detector | Nitrogen-Phosphorus Detector (NPD) | Maximum operating temperature | 400℃ |
| Detector | Nitrogen-Phosphorus Detector (NPD) | Detection limit | N:≤1×10^(-12)g(N)/s(Azonaphthalene) P:≤5×10^(-13)g(P)/s(Malathion) |
| Detector | Nitrogen-Phosphorus Detector (NPD) | Dynamic Linear Range | N≥10^(3)、P≥10^(3) |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.
Chromatography Systems & Consumables by Infitek. Match the analytical method, detector, column and sample-handling configuration.