Infitek Fluorescence Spectrophotometer, SP-LF97,SP-LF97PRO,SP-LF97XP is listed in VVON's spectrometers & optical analysis range for Bangladesh. Published models: SP-LF97, SP-LF97XP, SP-LF97PRO. Compare measurement range, optical configuration, sample format and software. For a quotation, send the analytical method, measurement range, sample format and software requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications 1
ModelSP-LF97SP-LF97XPSP-LF97PRO
Excitation Source150W xenon lamp(Hamamatsu)150W xenon lamp(Hamamatsu)150W xenon lamp(Hamamatsu)
Excitation Wavelength200nm~900nm200nm~900nm200nm~900nm
Emission Wavelength200nm~900nm200nm~900nm200nm~900nm
Excitation Slit10nm2nm、5nm、10nm、20nm2nm、5nm、10nm、20nm
Emission Slit10nm2nm、5nm、10nm、20nm2nm、5nm、10nm、20nm
Wavelength Accuracy±1.0nm±0.4nm±1.0nm
Wavelength Repeatability≤0.5nm≤0.2nm≤0.5nm
Signal-to-Noise RatioS/N≥150(10nm Slit)(P-P)S/N≥200(10nm Slit)(P-P)S/N≥150(10nm Slit)(P-P)
Signal-to-Noise RatioS/N≥1000(10nm Slit)(RMS)S/N≥1200(10nm Slit)(RMS)S/N≥1000(10nm Slit)(RMS)
Signal-to-Noise RatioS/N≥10000(10nm Slit)(RMSBG)S/N≥12000(10nm Slit)(RMSBG)S/N≥10000(10nm Slit)(RMSBG)
Detection Limit≤1×10-10 g/ml(Quinine Sulfate Solution)≤5×10-11 g/ml(Quinine Sulfate Solution)≤1×10-10 g/ml(Quinine Sulfate Solution)
Excitation Source150W xenon lamp(Hamamatsu)150W xenon lamp(Hamamatsu)150W xenon lamp(Hamamatsu)
Linearityγ≥0.995γ≥0.995γ≥0.995
Peak Repeatability≤1.5%≤1.5%≤1.5%
Stability(10min)Zero Drift: ±0.3Zero Drift: ±0.3Zero Drift: ±0.3
Stability(10min)Value Limit: ±1.5%Value Limit: ±1.5%Value Limit: ±1.5%
Wavelength Scan SpeedMulti-speed Level, Maximum at 48000nm/minMulti-speed Level, Maximum at 48000nm/minMulti-speed Level, Maximum at 48000nm/min
Photometric Quantity Range0.00-10000.000.00-10000.000.00-10000.00
Data TransportationUSB2.0USB2.0USB2.0
Power110-240V AC.50/60Hz, 200W110-240V AC.50/60Hz, 200W110-240V AC.50/60Hz, 200W
Instrument Dimension(mm)380×445×310380×445×310380×445×310
N.W./G.W.(kg)12/1412/1412/14
Manufacturer specifications 2
AccessoriesFunctions
Single sample rackConventional liquid fluorescence sample
Multi purpose fluorescent sample rack holderBase holder for other racks
Octave FiltersRemove the interference of frequency doubling
Membrane sample rackFor membrane sample
Powder sample rackFor powder samples
Auto Polarization filterAdjust the polarization light

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment

View full category