Skip to main content

Infitek Benchtop pH/Ion Meter, BEP-M300B

Brand: Infitek | Category: Scientific & Laboratory Equipment

Infitek Benchtop pH/Ion Meter, BEP-M300B is listed in VVON's ph conductivity & water analysis range for Bangladesh. Published models: BEP-M300B, 701 Na+, PF-202-C, PF-202, PNH3 -1-01, PF-2-01. Compare the remaining models in the specification tables. Published details include Temperature / Range: -5.0 to 110 ºC, 23.0 to 230 ºF. Match measured parameters, range, probe compatibility and sample conditions. For a quotation, send the water or sample type, parameters, range, probe and calibration requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications 1
ModelBEP-M300B
ParameterspH/ISE/Temp.(mV/pX)
pH / Range-2.00 to 20.00 pH
pH / Resolution0.1, 0.01 pH
pH / Accuracy±0.01 pH
pH / Calibration PointsUp to 5
pH / Standard CustomizationYes
pH / Standard RecognitionNIST, GB, DIN, USA and buffers
mV / Range-2000.0 to 2000.0 mV
mV / Resolution0.1
mV / Accuracy±0.1% or ±0.3 mV of reading whichever is greater
pX / Range-2.00 to 20.00 pX
pX / Resolution0.1, 0.01 pX
pX / Accuracy±0.01 pX
pX / Calibration PointsUp to 5
ISE / Range1E-9 to 9.999E9
ISE / Unitmol/L, mmol/L, g/L, mg/L, μg/L, ppm
ISE / ResolutionUp to 4 significant digits
ISE / Accuracy±0.5%
ISE / Calibration PointsUp to 5
Temperature / Range-5.0 to 110 ºC, 23.0 to 230 ºF
Temperature / UnitºC, ºF
Temperature / Resolution0.1
Temperature / Accuracy±0.2
Measurement / Reading ModeAuto Read (Fast, Medium, Slow), Timed, Continuous
Measurement / Reading PromptsReading, Stable, Locked
Measurement / Temp. CompensationATC, MTC
Data management / Data Storage500 results each
Data management / GLP FeaturesYes
Inputs / ElectrodeBNC(Q9)
Outputs / USBPC
Outputs / RS 232printer
Display options / BacklightYes
Display options / Auto Shutdown1~60 min, off
Display options / IP RatingIP54
Display options / Date and TimeYes
General / ElectricityAC Adapter, 100-240V AC input, DC9V output
General / Dimensions242×195×68 mm
General / Weight900g
General / Package Dimension (W*D*H)460×280×350mm
General / G.W.4kg
Manufacturer specifications 2
Matched electrode (Required option)Matched electrode (Required option)Matched electrode (Required option)Matched electrode (Required option)Matched electrode (Required option)
ModelTypeMeasuring rangeElectrode plugNotes
701 Na+Composite electrode1*10^(-6)-0.1mol/LBNC (Type Q9)
PF-202-CComposite electrode1*10^(-6)-0.1mol/LBNC (Type Q9)
PF-202Composite electrode1*10^(-6)-0.1mol/LBNC (Type Q9)
PNH3 -1-01Composite electrode5*10^(-6)-0.1mol/LBNC (Type Q9)
PF-2-01Single Electrode1*10^(-6)-0.1mol/LBNC (Type Q9)Used with reference electrode 232-01-X
PF-3-01Single Electrode1*10^(-6)-0.1mol/LBNC (Type Q9)Used with reference electrode 232-01-X
PCl-1-01Single Electrode5*10^(-5)-0.1mol/LBNC (Type Q9)Used with reference electrode C(K2SO4)-1-X
PBr-1-01Single Electrode5*10^(-6)-0.1mol/LBNC (Type Q9)Used with reference electrode 217-01-X
PI-1-01Single Electrode5*10^(-7)-0.1mol/LBNC (Type Q9)Used with reference electrode 217-01-X
PK-1-01Single Electrode1*10^(-5)-0.1mol/LBNC (Type Q9)Used with reference electrode 217-01-X
PCa-1-01Single Electrode1*10^(-5)-0.1mol/LBNC (Type Q9)Used with reference electrode 232-01-X
PCu-1-01Single Electrode5*10^(-7)-0.1mol/LBNC (Type Q9)Used with reference electrode C(K2SO4)-1-X
PPb-1-01Single Electrode5*10^(-7)-0.1mol/LBNC (Type Q9)Used with reference electrode 217-01-X
PNO3 -1-01Single Electrode1*10^(-5)-0.1mol/LBNC (Type Q9)Used with reference electrode 232-01-X
PClO4-1-01Single Electrode5*10^(-6)-0.1mol/LBNC (Type Q9)Used with reference electrode 217-01-X
PAg/S-1-01Single Electrode3×10^(-7)mol/L-0.1mol/LBNC (Type Q9)Used with reference electrode C(K2SO4)-1-X
PBF4-1-01Single Electrode3×10^(-6)mol/L-0.1mol/LBNC (Type Q9)Used with reference electrode 232-01-X
PCN-1-01Single Electrode1*10^(-6)-1*10^(-2)mol/LBNC (Type Q9)Used with reference electrode 217-01-X
972101 F-Composite electrode1×10^(-6)mol/L-saturatedBNC (Type Q9)
972102 Cl-Composite electrode5*10^(-5)-1mol/LBNC (Type Q9)
972103 Br-Composite electrode2*10^(-6)-1mol/LBNC (Type Q9)
972104 I-Composite electrode1*10^(-7)-1mol/LBNC (Type Q9)
972105 Cu+Composite electrode1*10^(-7)-0.1mol/LBNC (Type Q9)
972106 PbComposite electrode1*10^(-6)-0.1mol/LBNC (Type Q9)
972207 Na+Composite electrode1×10^(-7)mol/L-saturatedS7
972121 K+Composite electrode1×10^(-6)-1mol/LBNC (Type Q9)
972122 (NH4+)Composite electrode1×10^(-6)-1mol/LBNC (Type Q9)
972123 NO₃⁻Composite electrode1×10^(-5)-1mol/LBNC (Type Q9)
972124 Ca2+Composite electrode5*10^(-7)-1mol/LBNC (Type Q9)
972125 BF4–Composite electrode1×10^(-6)-0.1mol/LBNC (Type Q9)
972126 ClO4–Composite electrode1×10^(-5)-0.1mol/LBNC (Type Q9)
972140 NH3 –Composite electrode1×10^(-6)-1mol/LBNC (Type Q9)
972150 Residual chlorine electrodeComposite electrode(0.01-20) ppm (as chlorine gas)BNC (Type Q9)

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment

View full category