Brand: Infitek | Category: Scientific & Laboratory Equipment
Infitek Benchtop Conductivity/TDS Meter, BEP-M510,BEP-M950 is listed in VVON's ph conductivity & water analysis range for Bangladesh. Published models: BEP-M510, BEP-M950. Match measured parameters, range, probe compatibility and sample conditions. For a quotation, send the water or sample type, parameters, range, probe and calibration requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BEP-M510 | BEP-M950 |
|---|---|---|
| Conductivity / Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Conductivity / Resolution | 0.001, 0.01, 0.1, 1 | 0.001, 0.01, 0.1, 1 |
| Conductivity / Accuracy | ±1% F.S. | ±0.5% F.S. |
| Conductivity / Calibration Points | 1 to 3 points | 1 to 5 points |
| Conductivity / Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS / Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| TDS / Resolution | 0.01, 0.1, 1 | 0.01, 0.1, 1 |
| TDS / Accuracy | ±1%F.S. | ±1%F.S. |
| TDS / TDS Factor | 0.1~1.0 (default 0.5) | 0.1~1.0 (default 0.5) |
| Salinity / Range | — | 0.00~42.00psu, 0.00~80.00ppt |
| Salinity / Resolution | — | 0.01 |
| Salinity / Accuracy | — | ±1% F.S. |
| Resistivity / Range | — | 0.00~20.00MΩ |
| Resistivity / Resolution | — | 0.01 |
| Resistivity / Accuracy | — | ±1% F.S. |
| Temperature / Range | 0~105°C/32~221°F | 0~105°C/32~221°F |
| Temperature / Resolution | 0.1°C/0.1°F | 0.1°C/0.1°F |
| Temperature / Accuracy | ±1°C/±1.8°F | ±0.5°C/±0.9°F |
| Temperature / Offset Calibration | 1 point, reading ±10°C | 1 point, reading ±10°C |
| Other Specifications / Temperature Compensation | 0~100°C, manual or automatic | 0~100°C, manual or automatic |
| Other Specifications / Temperature Coefficient | Linear (0.0~10.0%/°C) | Linear (0.0~10.0%/°C), pure water |
| Other Specifications / Reference Temperature | 25°℃ | 20/25°C |
| Other Specifications / Cell Constant | K=0.1,1,10 or custom | K=0.1,1,10 or custom |
| Other Specifications / Stability Criteria | 一 | Low or high |
| Other Specifications / Calibration Due Alarm | 一 | 1 to 31 days or off |
| Other Specifications / Calibration Factor Display | 一 | Yes |
| Other Specifications / Hold Function | Manual or auto-endpoint | Manual or auto-endpoint |
| Other Specifications / Memory | 一 | 500 data sets |
| Other Specifications / Communication Interface | 一 | uSB |
| Other Specifications / Connector | 6-pin mini-DIN, 3.5mm jack socket | 6-pin mini-DIN,3.5mm jack socket |
| Other Specifications / Display | Custom LCD (120×60mm) | Custom LCD (125×100mm) |
| Other Specifications / Power Requirements | DC9V power adapter | DC5V power adapter |
| Other Specifications / Dimensions | 210(L)×205(W)×75(H)mm | 210(L)×188(W)×60(H)mm |
| Other Specifications / Weight | 1.5kg | 1.5kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about Infitek equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd