Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Ultrapure Water Purifier SCSJ-10L SCSJ-20L SCSJ-30L is listed in VVON's laboratory water purification range for Bangladesh. Published models: Standard SCSJ-10L SCSJ-20L SCSJ-30L, Eliminating Endotoxin SCSJ-10F SCSJ-20F SCSJ-30F, Low TOC SCSJ-10V SCSJ-20V SCSJ-30V, Synthesizing SCSJ-10VF SCSJ-20VF SCSJ-30VF. Match feed water, required water quality, daily demand and consumable replacements. For a quotation, send the feed-water quality, required water specification and litres per day. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | Standard SCSJ-10L SCSJ-20L SCSJ-30L | Eliminating Endotoxin SCSJ-10F SCSJ-20F SCSJ-30F | Low TOC SCSJ-10V SCSJ-20V SCSJ-30V | Synthesizing SCSJ-10VF SCSJ-20VF SCSJ-30VF |
|---|---|---|---|---|
| Output(25°C) | 10 series-10L/H, 20 series-20L/H, 30 series-30L/H | 10 series-10L/H, 20 series-20L/H, 30 series-30L/H | 10 series-10L/H, 20 series-20L/H, 30 series-30L/H | 10 series-10L/H, 20 series-20L/H, 30 series-30L/H |
| Flow Rate | Up to 2 liters/minute(with pressure tank) | Up to 2 liters/minute(with pressure tank) | Up to 2 liters/minute(with pressure tank) | Up to 2 liters/minute(with pressure tank) |
| Water Output Type | RO and ultra-pure water | RO and ultra-pure water | RO and ultra-pure water | RO and ultra-pure water |
| Resistivity(25°C) | 18.2MΩ.cm | 18.2MΩ.cm | 18.2MΩ.cm | 18.2MΩ.cm |
| TOC* | <10ppb | <10ppb | <3ppb | <3ppb |
| Bacteria | <0.1cfu/ml | <0.1cfu/ml | <0.1cfu/ml | <0.1cfu/ml |
| Particle(>0.22μm) | <1/ml | <1/ml | <1/ml | <1/ml |
| Endotoxin | N/A | <0.001Eu/ml | N/A | <0.001Eu/ml |
| Ion Rejection Rate | 95%~99%(new RO membrane) | 95%~99%(new RO membrane) | 95%~99%(new RO membrane) | 95%~99%(new RO membrane) |
| Particles and Bacteria Rejection Rate | >99% | >99% | >99% | >99% |
| Water Supply Requirements | Tap water, TDS<200ppm, 5~45°C, 1.0~4.0kgf/cm^(2) | Tap water, TDS<200ppm, 5~45°C, 1.0~4.0kgf/cm^(2) | Tap water, TDS<200ppm, 5~45°C, 1.0~4.0kgf/cm^(2) | Tap water, TDS<200ppm, 5~45°C, 1.0~4.0kgf/cm^(2) |
| Standard Configuration | Main body(including 1 set of cartridge), 12 liters pressure tank | Main body(including 1 set of cartridge), 12 liters pressure tank | Main body(including 1 set of cartridge), 12 liters pressure tank | Main body(including 1 set of cartridge), 12 liters pressure tank |
| Purification System / Pretreatment Unit | 11" U type Quick-Insert PP Cotton Filter*1 11" U Type Quick-Insert Active Carbon Filter*2 | 11" U type Quick-Insert PP Cotton Filter*1 11" U Type Quick-Insert Active Carbon Filter*2 | 11" U type Quick-Insert PP Cotton Filter*1 11" U Type Quick-Insert Active Carbon Filter*2 | 11" U type Quick-Insert PP Cotton Filter*1 11" U Type Quick-Insert Active Carbon Filter*2 |
| Purification System / RO Unit | 75 GPD RO membrane*1(for 10L) 150 GPD RO membrane*1(for 20L) 200 GPD RO membrane*1(for 30L) | 75 GPD RO membrane*1(for 10L) 150 GPD RO membrane*1(for 20L) 200 GPD RO membrane*1(for 30L) | 75 GPD RO membrane*1(for 10L) 150 GPD RO membrane*1(for 20L) 200 GPD RO membrane*1(for 30L) | 75 GPD RO membrane*1(for 10L) 150 GPD RO membrane*1(for 20L) 200 GPD RO membrane*1(for 30L) |
| Purification System / Subsequent Unit | 11" U Type Quick-Insert Ultra Purification Column*4 0.2μm PES terminal filter*1 Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series) Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series) | 11" U Type Quick-Insert Ultra Purification Column*4 0.2μm PES terminal filter*1 Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series) Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series) | 11" U Type Quick-Insert Ultra Purification Column*4 0.2μm PES terminal filter*1 Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series) Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series) | 11" U Type Quick-Insert Ultra Purification Column*4 0.2μm PES terminal filter*1 Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series) Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series) |
| Consumption | 48~72W | 48~72W | 48~72W | 48~72W |
| Power Supply | AC110/220V±10%, 50/60Hz | AC110/220V±10%, 50/60Hz | AC110/220V±10%, 50/60Hz | AC110/220V±10%, 50/60Hz |
| External Size(W*D*H) | 410*270*500mm | 410*270*500mm | 410*270*500mm | 410*270*500mm |
| Package Size(W*D*H) | 550*630*750mm | 550*630*750mm | 550*630*750mm | 550*630*750mm |
| Gross Weight | 40kg | 40kg | 40kg | 40kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd