Brand: BIOBASE | Category: Medical Equipment
BIOBASE The injection pump is listed in VVON's patient monitoring & critical care range for Bangladesh. Published models: DPfusion SP1. Published details include Total Volume Range: 0.1-9999.9ml (0.1 ml step); Bolus Volume: Range: 1.0~50.0ml, (0.1ml step). Confirm the intended care setting, functions, accessories and operator training needs. For a quotation, send the care setting, patient group, required functions and accessories. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | DPfusion SP1 |
|---|---|
| Applicable Syringes | 5ml,10ml,20ml,30ml,50ml,60ml of any standard |
| Accuracy | +/- 2% with correct calibration |
| Rate Mode | 50ml(60ml):0.1ml/h-2000.0ml/h (0.1ml/h or 1ml/h step) 30ml:0.1ml/h-1200.0ml/h (0.1ml/h or 1ml/h step); 20ml:0.1ml/h-800.0ml/h (0.1ml/h or 1ml/h step); 10ml:0.1ml/h-400.0ml/h (0.1ml/h or 1ml/h step) 5ml: 0.1~200ml/h (0.1ml/h or 1ml/h step) (Programmable 0.01ml/h~9999.9ml/h) |
| Time Mode | SOL. VOL:0.1-9999.9ml (0.1ml step); TIME:00:01-99:59min (1min step) |
| Dose Mode: | Volume:0.1-999.9ml(0.1ml step); DRUG MASS:0.1-999.9mg 0.1mg step); DOSE:0.001-9999ug/kg/min(0.001ug/kg/min step); WEIGHT:0.1-300kg(0.1kg the least step) Dose unit: ng/kg/min, ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h,g/kg/h,ug/min,mg/min,g/min,ug/h,mg/h,g/h,U/min,U/h,IU/h,U/kg/h,ml/h |
| Total Volume Range | 0.1-9999.9ml (0.1 ml step) |
| Purge Rate | 50ml(60ml):1500.0ml/h, 30ml:1200.0ml/h, 20ml:800.0ml/h 10ml:400.0ml/h, 5ml: 200ml/h Programmable and adjustable |
| KVO Rate | 0.1~5.0 ml/h, Programmable and adjustable |
| DPS Dynamic Pressure | 20 levels setting |
| Alarms | Syringe Holder Loose ,Syringe Plunger Disengagement, Syringe Flange Insertion Error ,Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Infusion Complete, Syringe Near Empty, No Action, Battery Low Three levels of alarm volume LOW, MEDIUM or HIGH |
| Bolus Rate | 5ml: 0.1~200ml/h,10ml:0.1-400ml/h,20ml:0.1-800ml/h, 30ml:0.1-1200ml/h,50ml(60ml):0.1-2000ml/h Programmable and adjustable, Automatic/Manual bolus available |
| Bolus Volume | Range: 1.0~50.0ml, (0.1ml step) |
| Interface | RS-232 |
| Brightness | 1~10 levels can be selected |
| History Records | 2000 events stored can be checked and downloaded |
| Power Supply | AC power supply: AC 100 to 240V( +/-10%),50/60Hz; DC Power supply: 12~15V, power>15W; Built-in Lithium Battery: Rechargeable, 7.4 V, 2600mAh. 8 hours of continuous operation |
| Accessories: | AC power line, Operational manual |
| Protection Class | Class I, Type CF,IP44 |
| Dimension | 240*150*117mm, each unit |
| N.W | 2.0kg, each unit |
| Packing size | 300*260*160mm, each unit |
| G.W | 3.0kg, each unit |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Patient Monitoring & Critical Care by BIOBASE. Confirm the intended care setting, functions, accessories and operator training needs.
Patient Monitoring & Critical Care by BIOBASE. Confirm the intended care setting, functions, accessories and operator training needs.
Patient Monitoring & Critical Care by BIOBASE. Confirm the intended care setting, functions, accessories and operator training needs.