Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE Potential Titrator Ti-50 is listed in VVON's moisture analysis & titration range for Bangladesh. Published models: Ti-50. Published details include Burette Volume Accuracy: 10ml burette: ±0.025ml 20ml burette: ±0.035ml. Match sample matrix, measurement method, concentration range and reagent needs. For a quotation, send the sample matrix, method, concentration range and throughput. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | Ti-50 |
|---|---|
| Measuring Range | pH: 0.000~14.000pH mV: -1999.90~1999.90mV Temp: -5.0~105.0°C |
| Measuring Resolution | mV: 0.01mV pH: 0.001pH Temp: 0.1°C |
| Measuring Accuracy | pH: ±0.01pH ±1 bit mV: ±0.03% (full scale) Temp: ±0.3°C |
| Burette Volume Accuracy | 10ml burette: ±0.025ml 20ml burette: ±0.035ml |
| Burette Supplementary Speed | 55±10s(when burette is full scale) |
| Reproducibility of Titration Analysis | 0.2% |
| Reproducibility of Electric Unit | ≤0.2mV |
| Stability of Electric Unit | ±0.3 mV±1 bit/3h |
| Sensitive of Control Titration | ±2mV |
| Environments Temperature | 5.0~35.0 °C |
| Relative Humidity | ≤80% |
| Power Supply | AC100~240V, 50/60Hz |
| External Size(W*D*H) / Main Titration Device | 340*400*400mm |
| External Size(W*D*H) / Auxiliary Titration Device | 200*110*230mm |
| Package Size(W*D*H) | 570*520*520mm |
| Net Weight | 10kg |
| Gross Weight | 16kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Moisture Readability: 0.01%. Match sample matrix, measurement method, concentration range and reagent needs.
Volumetric Titration / Range: 0.1mg~250mg; Volumetric Titration / Polarization Current Accuracy: 1μA±0.2μA; 50μA±10μA. Match sample matrix, measurement method, concentration range and reagent needs.
Moisture Analysis & Titration by BIOBASE. Match sample matrix, measurement method, concentration range and reagent needs.