BIOBASE Portable pH/lon Meter is listed in VVON's ph conductivity & water analysis range for Bangladesh. Published models: PH-320, PH-321. Match measured parameters, range, probe compatibility and sample conditions. For a quotation, send the water or sample type, parameters, range, probe and calibration requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelPH-320PH-321
pH / pH Range-2.000~20.000pH/
pH / pH Accuracy±0.002pH/
pH / Resolution0.1, 0.01, 0.001pH, Selectable/
pH / Calibration Points1~5 points/
pH / pH Buffer OptionsUSA(pH1.68/4.01/7.00/10.01/12.45) NIST(pH1.68/4.01/6.86/9.18/12.45) DIN(pH1.09/4.65/6.79/9.23/12.75) or 2 custom buffers/
mV(ORP probe optional) / mV Range-1999.9~1999.9mV-1999.9~1999.9mV
mV(ORP probe optional) / Relative mV Range-1999.9~1999.9mV-1999.9~1999.9mV
mV(ORP probe optional) / mV Accuracy±0.2mV±0.2mV
mV(ORP probe optional) / Resolution0.1, 1mV, Selectable0.1, 1mV, Selectable
mV(ORP probe optional) / Calibration Points1 point(Only for Relative mV mode)1 point(Only for Relative mV mode)
Ion(Optional) / Ion Concentration Range0.001~19999(Depending on the range of ISE)0.001~19999(Depending on the range of ISE)
Ion(Optional) / Ion Concentration Accuracy±0.5% F.S(Monovalent), ±1% F.S(Divalent)±0.5% F.S(Monovalent), ±1% F.S(Divalent)
Ion(Optional) / Calibration Points2~5 points2~5 points
Ion(Optional) / Calibration Solutions0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000(ppm, mg/L, mol/L, mmol/L)0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000(ppm, mg/L, mol/L, mmol/L)
Temperature / Temperature Range0~105°C/32~221°F0~105°C/32~221°F
Temperature / Temperature Accuracy±0.5°C/±0.9°F±0.5°C/±0.9°F
Temperature / Resolution0.1°C/0.1°F0.1°C/0.1°F
Temperature / Offset Calibration1 point, reading ±10°C1 point, reading ±10°C
Other Specifications / Temperature Compensation0~100°C, manual or automatic0~100°C, manual or automatic
Other Specifications / Stability CriteriaLow or highLow or high
Other Specifications / Calibration Due Alarm1 to 31 days or off1 to 31 days or off
Other Specifications / Slope/Offset DisplayYesYes
Other Specifications / Hold FunctionManual or auto-endpointManual or auto-endpoint
Other Specifications / Auto-Off10, 20 or 30 minutes after last key pressed10, 20 or 30 minutes after last key pressed
Other Specifications / Memory500 data sets500 data sets
Other Specifications / Communication InterfaceUSBUSB
Other Specifications / ConnectorBNC, 3.5mm jack socketBNC, 3.5mm jack socket
Other Specifications / DisplayCustom LCD(80*60mm)Custom LCD(80*60mm)
Other Specifications / Power Requirements3*1.5V AA batteries or DC5V power adapter3*1.5V AA batteries or DC5V power adapter
Other Specifications / Battery LifeApproximately 150 hours(Turn off the backlight)Approximately 150 hours(Turn off the backlight)
Other Specifications / External Size(W*D*H)170*85*30mm170*85*30mm
Other Specifications / Package Size(W*D*H)475*155*350mm475*155*350mm
Other Specifications / Net Weight300g300g
Other Specifications / Gross Weight2kg2kg

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Scientific & Laboratory Equipment

View full category