Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Fruit and Vegetable Respirometer is listed in VVON's food agriculture & feed analysis range for Bangladesh. Published models: BK-FVR3080A, CO2. Published details include Temp. / Measuring Range: -20~95°C. Match the sample matrix, analytical method, preparation and daily workload. For a quotation, send the sample matrix, target measurement, method and daily workload. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-FVR3080A |
|---|---|
| CO2 / Detection Principle | Infrared |
| CO2 / Measuring Range | 0~5000ppm |
| CO2 / Resolution | 1ppm |
| CO2 / Linearity | ≤±1%F·S |
| CO2 / Repeatability | ≤±1% |
| CO2 / Response Time | ≤15s |
| CO2 / Zero Shift | ≤±2%F·S/24h |
| CO2 / Destination Shift | ≤±2%F·S/24h |
| O2 / Detection Principle | Electrochemical |
| O2 / Measuring Range | 0~95% |
| O2 / Resolution | 0.01% |
| O2 / Linearity | ≤±2%F·S |
| O2 / Repeatability | ≤±1% |
| O2 / Response Time | 30s |
| O2 / Zero Shift | ≤±2%F·S/24h |
| O2 / Destination Shift | ≤±2%F·S/24h |
| Temp. / Measuring Range | -20~95°C |
| Temp. / Resolution | 0.1°C |
| Temp. / Accuracy | ±0.2°C |
| Humidity / Measuring Range | 0~85% |
| Humidity / Resolution | 0.1% |
| Humidity / Accuracy | ±0.2%F·S |
| Pre-Heating Time | 15min |
| Power Supply | AC220V, 50/60Hz(Standard); AC110V, 60Hz(Optional,external transformer) |
| Respiratory Chamber | Standard: Φ120*180mm(2L), Φ60*89mm(0.25L), Φ40*80mm(0.1L) |
| External Size(W*D*H) | 260*260*130mm |
| Package Size(W*D*H) | 550*400*250mm |
| Net Weight | 3.25kg |
| Gross Weight | 10kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Temp. Range: 5~300℃; Capacity: 6pcs/batch. Match the sample matrix, analytical method, preparation and daily workload.
Temp / Measuring Range: 0~50°C. Match the sample matrix, analytical method, preparation and daily workload.
Temp. Range: 5~300℃; Capacity: 6pcs/batch. Match the sample matrix, analytical method, preparation and daily workload.