Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Formaldehyde Emission Test Chamber is listed in VVON's laboratory incubators & growth chambers range for Bangladesh. Published models: BJPX-FE801-3. Published details include Temp Range: 15~40℃. Compare chamber capacity and required temperature, atmosphere, humidity or agitation. For a quotation, send the application, working volume, temperature and atmosphere requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BJPX-FE801-3 |
|---|---|
| Temp Range | 15~40℃ |
| Temp Accuracy | ±0.5℃ |
| Humidity Range | 40~80%RH |
| Humidity Accuracy | ±3%RH |
| Air Exchange Rate Range | 0.2~2m3/h(Air change rate 0.2~2 times/h) |
| Air Exchange Rate Accuracy | Ventilation rate±1% |
| Air Flow Rate | 0.1~2m/s |
| Air Rate Accuracy | ≤0.05m/s |
| Test Chamber Size | 1±0.02m3 |
| Internal Size | 800*1000*1150mm |
| Pressure | 10±5Pa |
| Sealing | Under 1KPa relative pressure, leakage rate ≤1* m3/min |
| Constant Temperature Box | Polyurethane and insulation board Outer wall: steel plate, white spraying Inner wall: 304 stainless steel plate |
| Background Concentrations | Formaldehyde<0.006mg/m3 TVOC<0.05mg/m3 Single VOC<0.005mg/m3 |
| Consumption | Starting power≤4kw Running power 2kw |
| Power Supply | Standard: 220V 50/60Hz Optional: 110V 50/60Hz |
| External Size | 1750*1150*1860mm |
| Net Weight | 450kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Capacity: 24 cards; Temp. Range: RT+5~60°C. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.
Capacity: 1±0.01m^(3); Temp. Range: 15~40℃. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.
Capacity: 24-well blood typing regent card(Compatible with 6-column and 8-column formats); Temp. Range: RT+5~60℃. Compare chamber capacity and required temperature, atmosphere, humidity or agitation.