Skip to main content

BIOBASE Dual Syringe pump

Brand: BIOBASE | Category: Medical Equipment

BIOBASE Dual Syringe pump

BIOBASE Dual Syringe pump is listed in VVON's patient monitoring & critical care range for Bangladesh. Published models: DPfusion SPD2. Published details include Total Volume Range: 0.1-9999.9ml (0.1 ml step); Bolus Volume: Range: 1.0~50.0ml, (0.1ml step). Confirm the intended care setting, functions, accessories and operator training needs. For a quotation, send the care setting, patient group, required functions and accessories. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelDPfusion SPD2
Applicable Syringes5ml,10ml,20ml,30ml,50ml,60ml of any standard. Built-in syringe brands can be customized by users.
Accuracy+/- 2% with correct calibration
Rate Mode50ml(60ml):0.1ml/h-2000.0ml/h (0.1ml/h or 1ml/h step) 30ml:0.1ml/h-1200.0ml/h (0.1ml/h or 1ml/h step); 20ml:0.1ml/h-800.0ml/h (0.1ml/h or 1ml/h step); 10ml:0.1ml/h-400.0ml/h (0.1ml/h or 1ml/h step) 5ml: 0.1~200ml/h (0.1ml/h or 1ml/h step) (Programmable 0.01ml/h~9999.9ml/h)
Time ModeSOL. VOL:0.1-9999.9ml (0.1ml step); TIME:00:01-99:59min (1min step)
Dose Mode:Volume:0.1-999.9ml(0.1ml step); DRUG MASS:0.1-999.9mg 0.1mg step); DOSE:0.001-9999ug/kg/min(0.001ug/kg/min step); WEIGHT:0.1-300kg(0.1kg the least step) Dose unit: ng/kg/min, ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h,g/kg/h,ug/min,mg/min,g/min,ug/h,mg/h,g/h,U/min,U/h,IU/h,U/kg/h,ml/h
Total Volume Range0.1-9999.9ml (0.1 ml step)
Drug Library Mode10 categories of drugs, 17kinds of dose units. Can be customized by users. Makes drug dispensing more convenient and safer.
Sequential ModeAvailable
Purge Rate50ml(60ml):1500.0ml/h, 30ml:1200.0ml/h, 20ml:800.0ml/h 10ml:400.0ml/h, 5ml: 200ml/h Programmable and adjustable
KVO Rate0.1~5.0 ml/h, Programmable and adjustable, and KVO function can be disabled by users.
DPS dynamic pressure25 levels setting (20Kpa~160Kpa)
AlarmsSyringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Infusion Complete, Syringe Near Empty, No Action, Battery Low Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate5ml: 0.1~200ml/h,10ml:0.1-400ml/h,20ml:0.1-800ml/h, 30ml:0.1-1200ml/h,50ml(60ml):0.1-2000ml/h Programmable and adjustable, Automatic/Manual bolus available
Bolus VolumeRange: 1.0~50.0ml, (0.1ml step)
InterfaceRS-232
Brightness1~10 levels can be selected
History Records2000 events stored can be checked and downloaded
Power SupplyAC power supply: AC 100 to 240V( +/-10%),50/60Hz; DC Power supply: 12~15V, power>15W; Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh. 8 hours of continuous operation
Accessories:AC power line, Operational manual
Protection ClassClass I, Type CF, IP44
Dimension350*150*220mm
N.W4kg
Packing Size400*200*250mm
G.W4.5kg

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd

Back to Medical Equipment

View full category