Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE Automatic Titrator BK-PT10 BK-PT11 is listed in VVON's moisture analysis & titration range for Bangladesh. Published models: BK-PT10, BK-PT11. Match sample matrix, measurement method, concentration range and reagent needs. For a quotation, send the sample matrix, method, concentration range and throughput. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-PT10 | BK-PT11 |
|---|---|---|
| pH / Range | -2.000~+20.000pH | -2.000~+20.000pH |
| pH / Resolution | 0.001pH | 0.001pH |
| pH / Accuracy | ±0.01pH | ±0.01pH |
| ORP / Range | -2000.0~+2000.0mV | -2000.0~+2000.0mV |
| ORP / Resolution | 0.1mV | 0.1mV |
| ORP / Accuracy | ±0.1mV±0.03%FS | ±0.1mV±0.03%FS |
| Temperature / Range | -5~120℃ | -5~120℃ |
| Temperature / Resolution | 0.1℃ | 0.1℃ |
| Temperature / Accuracy | ±0.1℃ | ±0.1℃ |
| Burette / Specification | 10ml(Standard); 20ml(Optional) | 10ml(Standard) |
| Burette / Resolution | 1/96000 | 1/96000 |
| Burette / Supplementary Speed | 16s (when burette is full scale) | 16s (when burette is full scale) |
| Titration Repeatability | ≤0.2% | ≤0.2% |
| Electronic Unit Repeatability Error | ≤0.2mV | ≤0.2mV |
| Electronic Unit Stability | ±0.3mV/3h | ±0.3mV/3h |
| Stirring Method | Magnetic stirring | Magnetic stirring |
| Interface Type | mV/pH measuring electrode interface, reference electrode interface, temperature electrode interface, USB port, power port | mV/pH measuring electrode interface, reference electrode interface, temperature electrode interface, USB port, power port |
| Package Size(W*D*H) | 545*457*460mm | 550*490*415mm |
| Net Weight | 13kg | 6kg |
| Gross Weight | 15kg | 11kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Titration Volume Accuracy: 0.001ml; Titration Cup Capacity: 250ml. Match sample matrix, measurement method, concentration range and reagent needs.
Volume Range: 0.01mL-99.99mL, Max piston lift is 10mL, resolution is 10μL; Volume Accuracy: R=0.2% CV=0.07%. Match sample matrix, measurement method, concentration range and reagent needs.
Moisture Analysis & Titration by BIOBASE. Match sample matrix, measurement method, concentration range and reagent needs.