Brand: BIOBASE | Category: Scientific & Laboratory Equipment
BIOBASE Automated NGS Library Preparation Workstation (Customized) is listed in VVON's pipettes & liquid handling range for Bangladesh. Published models: Auto-NGS 200. Compare volume range, channels, liquid compatibility and required consumables. For a quotation, send the volume range, liquid type, channels, consumables and quantity. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Item | Specification |
|---|---|
| Model | Auto-NGS 200 |
| Throughput | 1~96 |
| Tiles number | 25 standard tiles + (TIP off box + waste liquid area) |
| Pipettor | Specification: 200 µL; 24-channel (can be used as a single channel)Pipetting range: 50 µL tip: 1-200 µL; 200 µL tip: 2-200 µLMinimum detection volume: 20 µL |
| Pipetting precision | 1 µL: ≤8 %; 2 µL: ≤5 %; 5 µL: ≤4 %; 20 µL: ≤1 %; 100 µL: ≤1 %; 200 µL: ≤1 % |
| Pipetting accuracy | 1 µL: ±10 %; 2 µL: ±8 %; 5 µL: ±4 %; 20 µL: ±2 %; 100 µL: ±1 %; 200 µL: ±1 % |
| Temperature control block | Including 2 temperature control blocksTemperature control range: 4~105 °CTemperature control accuracy: ≤1 °CTemperature control uniformity: ≤1 °C @55 °C |
| Gene amplification block | Temperature control range: thermo lid: +30 °C~+120 °C; block: +4 °C~+99 °CUniformity: ≤0.7 °CAccuracy: ≤±0.3 °C |
| Fluorescence detection range | 0.4 ng~100 ng |
| Automatic clamping and heating mixing block | Yes |
| Magnetic plate | 96-well annular magnetic plate |
| Gripper | Including one |
| Stacking plate lifting block | Including one |
| UV sterilization | Equipped with UV sterilization lamp, HEPA device |
| Instrument port | USB port |
| Information management | External scanner for entering sample/reagent informationExpandable LIS system connectionExpandable cloud database connection |
| Ambient condition | Temperature requirement: 20±5 °CRelative humidity: ≤80% |
| Power input | 100~240 V, 50 / 60 Hz, rated power 1200 W |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Dispensing Volume: 5~9999μl(1μl increment). Compare volume range, channels, liquid compatibility and required consumables.
Pipetting Volume: 5~200μl. Compare volume range, channels, liquid compatibility and required consumables.
Pipettes & Liquid Handling by BIOBASE. Compare volume range, channels, liquid compatibility and required consumables.