Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Atomic Absorption Spectrophotometer BK-AA4530F is listed in VVON's spectrometers & optical analysis range for Bangladesh. Published models: BK-AA4530F. Published details include Wavelength Range: 190~900nm; Max Heating Speed: ≥2000°C/S. Compare measurement range, optical configuration, sample format and software. For a quotation, send the analytical method, measurement range, sample format and software requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-AA4530F |
|---|---|
| Wavelength Range | 190~900nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0 and 2.0nm |
| Wavelength Accuracy | ≤±0.15nm |
| Wavelength Repeatability | ≤0.04nm |
| Base Line Stability | ≤0.002A/30min(Cu) |
| Characteristic Concentration | 0.02μg/ml/1%(Cu) |
| Detection Limit | 0.004μg/ml(Cu) |
| Preciseness | 0.5% |
| Grating | 1800 lines/mm |
| Inflamer | All-metal titanium burner |
| Atomizer | Effective glass atomizer |
| Lamp Stand | 8 |
| D2 Background Calibration | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
| Power Supply | 220V, 50Hz |
| Packing Size(W*D*H) | 860*705*755mm(Main instrument); 1170*650*900mm(Accessories) |
| Gross Weight | 100.8kg(Main instrument); 65kg(Accessories) |
| Standard Accessories | Software; Inkjet printer; Oil free air compressor; Acetylene reducing valve; Cu hollow cathode lamp; Air filter |
| Optional Accessories | Graphite furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler |
| Acetylene Air Burner | 100mm |
|---|---|
| Ignition Dynamic Baseline Drift | ≤0.006A/30min |
| Characteristic Concentration | ≤0.025μg/ml/1%(Cu) |
| Related Standard Deviation of the Accuracy | ≤0.5%(Cu, absorbance>0.8A) (Detection limit Cu≤0.008μg/ml) |
| Safety System | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner |
| Max. Temperature | 3000°C |
|---|---|
| Max Heating Speed | ≥2000°C/S |
| Characteristic Quantity | Cd≤0.5*10^(-12)g Cu≤0.5*10^(-11)g |
| Accuracy | Cu≤3% Cd≤3% |
| Safety System | Over current protection, Low air pressure alarm/protection, Low cooling water flow alarm/protection |
| Power Supply | 220V, 50Hz |
| Consumption | 7000W |
| Packing Size(W*D*H) | 730*625*700mm |
| Gross Weight | 79.3kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Spectrometers & Optical Analysis by BIOBASE. Compare measurement range, optical configuration, sample format and software.
Spectrometers & Optical Analysis by BIOBASE. Compare measurement range, optical configuration, sample format and software.
Spectrometers & Optical Analysis by BIOBASE. Compare measurement range, optical configuration, sample format and software.