Brand: BIOBASE | Category: Scientific & Laboratory Equipment

BIOBASE Atomic Absorption Spectrophotometer BK-AA180B is listed in VVON's spectrometers & optical analysis range for Bangladesh. Published models: BK-AA180B. Published details include Wavelength Range: 170~900nm. Compare measurement range, optical configuration, sample format and software. For a quotation, send the analytical method, measurement range, sample format and software requirements. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-AA180B |
|---|---|
| Wavelength Range | 170~900nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.8, 1.6, 2.4nm |
| Wavelength Accuracy | ±0.1nm |
| Wavelength Repeatability | ≤0.05nm |
| Detector | Photomultiplier tube detector |
| Baseline Stability | Drift ≤0.002Abs, noise ≤0.001Abs(Steady 30min) Drift ≤0.002Abs, noise ≤0.001Abs(Dynamic 15min) |
| Resolution | Spectral bandwidth deviation ≤0.02nm Manganese double line valley to peak energy ratio ≤25% |
| Characteristic Concentration | Flame method for Cu: ≤0.025μg/mL/1% |
| Detection Limit | Flame method for Cu: ≤0.002μg/mL |
| Preciseness | Flame method for Cu: ≤0.3% |
| Background Correction Ability | Deuterium lamp calibration 1.0Abs, background ≥90 times |
| Diffraction Grating | Groove 1800lines/mm, blaze wavelength 250nm |
| Lamp Stand | 8(Support simultaneous preheating of 1~4 lights) |
| Standard Accessory | Element lamp(Cu*1, Hg*1), software working station |
| Optional Accessory | Oxygen-enriched high-temperature flame, wide slit combustion head, adjustable nebulizer, hydride vapor generator, audit trailing software, oil-free air compressor, computer, printer |
| Power Supply | AC220V, 50/60Hz; 110V, 60Hz(Standard) |
| External Size(W*D*H) | 1080*480*560mm |
| Package Size(W*D*H) | 1220*670*840mm |
| Net Weight | 70kg |
| Gross Weight | 140kg |
| Air-acetylene Burner | 100mm all-titanium burner |
|---|---|
| Atomization Chamber System | Integrally molded from polyphenylene sulfide |
| Burner System | Flame height is adjustable and lockable, with a 360° rotatable combustion seam |
| Gas Flow Control System | Automatic ignition/fame-out |
| Reading Mode | Foot pedal operation |
| Safety System | Emergency shutdown protection switch, automatic gas cut-off/shutdown/alarm in case of abnormal status, abnormal air pressure, ignition failure, gas leakage, abnormal flow rate, etc. |
| Smart Optimization | One-key operation for instrument optimization, supporting multi-task analysis |
|---|---|
| Repeat Measurement | 1~99 replicates with auto-calculation of mean/SD/RSD |
| Print/Export Reports | Word/Excel supported |
| Auto-Calibration | Curve fitting, re-slope&concentration calculation, incl. standard addition method |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Back to Scientific & Laboratory Equipment
Wavelength Range: 170~900nm; Temp. Range: RT~3000℃. Compare measurement range, optical configuration, sample format and software.
Spectrometers & Optical Analysis by Infitek. Compare measurement range, optical configuration, sample format and software.