BIOBASE 5-Part Veterinary Hematology Analyzer BK-6310VET is listed in VVON's veterinary laboratory equipment range for Bangladesh. Published models: BK-6310VET. Check supported species, sample type, test menu and consumable compatibility. For a quotation, send the species, sample type, expected workload and consumables. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.

Model specifications

Compare each model column separately. Confirm options and included accessories in your quotation.

Manufacturer specifications
ModelBK-6310VETBK-6310VETBK-6310VETBK-6310VET
Throughput60 Tests/hour60 Tests/hour60 Tests/hour60 Tests/hour
Sample ProfileDog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkeyDog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkeyDog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkeyDog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkey
Assay Items5 parts, 25 parameters, 3 histograms, 3D scattergram5 parts, 25 parameters, 3 histograms, 3D scattergram5 parts, 25 parameters, 3 histograms, 3D scattergram5 parts, 25 parameters, 3 histograms, 3D scattergram
PrincipleTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB testTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB testTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB testTri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test
Test ModeCBC mode, CBC+DIFF mode Venous whole blood, predilutedCBC mode, CBC+DIFF mode Venous whole blood, predilutedCBC mode, CBC+DIFF mode Venous whole blood, predilutedCBC mode, CBC+DIFF mode Venous whole blood, prediluted
Sample VolumeCBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μlCBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μlCBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μlCBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μl
ParametersWBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC#WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC#WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC#WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC#
PerformanceItemLinearity rangeCarry OverCV
PerformanceWBC1~99.9*10^(9)/L≤0.5%≤2.0%
PerformanceRBC0.3~7*10^(12)/L≤0.5%≤1.5%
PerformanceHGB20~240g/L≤0.5%≤1.5%
PerformancePLT20~999*10^(9)/L≤1.0%≤4.0%
Storage300,000 results including histograms, scattergrams and patient information300,000 results including histograms, scattergrams and patient information300,000 results including histograms, scattergrams and patient information300,000 results including histograms, scattergrams and patient information
Interface4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader
SystemLINUS systemLINUS systemLINUS systemLINUS system
Power SupplyAC100~240V,50/60Hz, 300VAAC100~240V,50/60Hz, 300VAAC100~240V,50/60Hz, 300VAAC100~240V,50/60Hz, 300VA
Package Size(W*D*H)575*490*690mm575*490*690mm575*490*690mm575*490*690mm
Gross Weight46kg46kg46kg46kg
Reagent Package Size(W*D*H)315*315*280mm; 190*240*350mm315*315*280mm; 190*240*350mm315*315*280mm; 190*240*350mm315*315*280mm; 190*240*350mm
Reagent Gross Weight20kg; 1.5kg20kg; 1.5kg20kg; 1.5kg20kg; 1.5kg

Manufacturer catalogue checked 2026-09-28.

View on manufacturer website

Get a Quote

Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.

Useful details to share

Share what you know. You can start with your name and a phone number or email; final specifications can follow.

Request a Quote

Not sure which configuration you need? Help me choose

Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.

Phone: +8801805987890 | Email: info@vvon.com.bd