Brand: BIOBASE | Category: Medical Equipment

BIOBASE 5-Part Veterinary Hematology Analyzer BK-6310VET is listed in VVON's veterinary laboratory equipment range for Bangladesh. Published models: BK-6310VET. Check supported species, sample type, test menu and consumable compatibility. For a quotation, send the species, sample type, expected workload and consumables. Confirm the exact model, included accessories, consumables, delivery and service scope in the offer. Manufacturer specifications below describe the published configuration; options and local availability require confirmation.
Compare each model column separately. Confirm options and included accessories in your quotation.
| Model | BK-6310VET | BK-6310VET | BK-6310VET | BK-6310VET |
|---|---|---|---|---|
| Throughput | 60 Tests/hour | 60 Tests/hour | 60 Tests/hour | 60 Tests/hour |
| Sample Profile | Dog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkey | Dog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkey | Dog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkey | Dog, cat, camel, bird, horse, cattle, cow, goat, sheep, pig, mouse, monkey |
| Assay Items | 5 parts, 25 parameters, 3 histograms, 3D scattergram | 5 parts, 25 parameters, 3 histograms, 3D scattergram | 5 parts, 25 parameters, 3 histograms, 3D scattergram | 5 parts, 25 parameters, 3 histograms, 3D scattergram |
| Principle | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test | Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test |
| Test Mode | CBC mode, CBC+DIFF mode Venous whole blood, prediluted | CBC mode, CBC+DIFF mode Venous whole blood, prediluted | CBC mode, CBC+DIFF mode Venous whole blood, prediluted | CBC mode, CBC+DIFF mode Venous whole blood, prediluted |
| Sample Volume | CBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μl | CBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μl | CBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μl | CBC+DIFF mode: 19.8μl CBC mode: 10μl prediluted blood: 20μl |
| Parameters | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC# | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC# | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC# | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#. 4 research parameters: ALY%, ALY#, LIC%, LIC# |
| Performance | Item | Linearity range | Carry Over | CV |
| Performance | WBC | 1~99.9*10^(9)/L | ≤0.5% | ≤2.0% |
| Performance | RBC | 0.3~7*10^(12)/L | ≤0.5% | ≤1.5% |
| Performance | HGB | 20~240g/L | ≤0.5% | ≤1.5% |
| Performance | PLT | 20~999*10^(9)/L | ≤1.0% | ≤4.0% |
| Storage | 300,000 results including histograms, scattergrams and patient information | 300,000 results including histograms, scattergrams and patient information | 300,000 results including histograms, scattergrams and patient information | 300,000 results including histograms, scattergrams and patient information |
| Interface | 4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader | 4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader | 4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader | 4 USB ports, 1 LAN port, Bi-direction LIS, support HL7 protocol, Internal RFID reader |
| System | LINUS system | LINUS system | LINUS system | LINUS system |
| Power Supply | AC100~240V,50/60Hz, 300VA | AC100~240V,50/60Hz, 300VA | AC100~240V,50/60Hz, 300VA | AC100~240V,50/60Hz, 300VA |
| Package Size(W*D*H) | 575*490*690mm | 575*490*690mm | 575*490*690mm | 575*490*690mm |
| Gross Weight | 46kg | 46kg | 46kg | 46kg |
| Reagent Package Size(W*D*H) | 315*315*280mm; 190*240*350mm | 315*315*280mm; 190*240*350mm | 315*315*280mm; 190*240*350mm | 315*315*280mm; 190*240*350mm |
| Reagent Gross Weight | 20kg; 1.5kg | 20kg; 1.5kg | 20kg; 1.5kg | 20kg; 1.5kg |
Manufacturer catalogue checked 2026-09-28.
Request an itemised quotation covering the proposed configuration, availability, lead time and agreed supply and support scope.
Share what you know. You can start with your name and a phone number or email; final specifications can follow.
Not sure which configuration you need? Help me choose
Contact Vvon Technologies Limited about BIOBASE equipment requirements in Bangladesh.
Phone: +8801805987890 | Email: info@vvon.com.bd
Veterinary Laboratory Equipment by BIOBASE. Check supported species, sample type, test menu and consumable compatibility.
Veterinary Laboratory Equipment by BIOBASE. Check supported species, sample type, test menu and consumable compatibility.
Veterinary Laboratory Equipment by BIOBASE. Check supported species, sample type, test menu and consumable compatibility.